Petrochemical Application

Petrochemical Application

Take a 3-D animated tour of the various aspects of a Petrochemical facility. See our step-by-step illustrations of how our products are applied to Piperacks, Vertical Vessel Skirts, Support Legs for Vertical Vessels, Horizontal Vessels and Sphere Legs.

The animations contained herein are not intended to replace a thorough understanding of Isolatek application guidelines. For further information on all application methods contact Isolatek International or one of our business partners.

In order to obtain optimal results, the following spray equipment setup for CAFCO® FENDOLITE® M-II / ISOLATEK® TYPE M-II on Industrial, Chemical and Petrochemical processing sites is required:

CAFCO FENDOLITE TG / ISOLATEK TYPE TG is mixed and then hand applied using common masonry tools.

Stainless Steel Pins

Grade 316. Stainless steel mesh reinforcement pins

Galvanized Mesh

Plastic Coated Galvanized Hexagonal Mesh

Metal Lath

3.4 lbs. / sq. yard Diamond Metal Lath.

Corner Bead

Plastic nose to provide smooth and sturdy edges.

Sprayer Equipment Americas

Rotor stator type with open throat and screw feed.

Sprayer Equipment International

Rotor stator type with open throat and screw feed.

Nozzles / Guns

Minimum 1” ID aluminum pole to provide minimum volume of 15 cfm (420 L / min).

Hoses/ Couplings/ Reducers

High pressure grout hose for plaster, grout and cement applications. Screw-on type quick connect/disconnect couplings which do not restrict product flow reducers.

Careful preparation of substrates is important. Correct preparation ensures that the durability of the fire protection system is maintained and the required level of adhesion is achieved. Poorly prepared substrates may compromise the long term corrosion protection to the structure. Where mechanical fixings are attached to the substrate, careful attention is required in order to reinstate the corrosion system after the fixings have been attached. It is required that the substrates are prepared in accordance with Isolatek’s written instructions.

CAFCO® FENDOLITE® M-II / ISOLATEK® TYPE M-II does not cause corrosion to steel. However, for petrochemical environments, the steelwork must be suitably primed, painted or galvanized prior to the application of the CAFCO FENDOLITE M-II / ISOLATEK TYPE M-II System. All primer/paint systems must be fully cured in accordance with the manufacturers’ application instructions.

The substrate to be protected with the CAFCO FENDOLITE M-II / ISOLATEK Type M-II system must be prepared such that it is free from dirt, dust, oil or other contamination that would impair the adhesion of the CAFCO FENDOLITE M-II / ISOLATEK Type M-II system. Pre-existing protective primers and coatings must be sealed prior to the installation of the CAFCO FENDOLITE M-II / ISOLATEK Type M-II system with ISOLATEK® SBK-113 sealer / keycoat. As an alternate, a galvanized diamond lath may be installed as a substrate for the system.

The reinforcement system for steel structures is galvanized or plastic coated galvanized woven wire or hexagonal mesh. The mesh is secured to the steel by use of stud welded, helical or powder actuated fasteners. The reinforcing mesh is held to the substrate at the fixing points, and then pulled away from the substrate to the middle third of the total thickness of the CAFCO FENDOLITE M-II / ISOLATEK TYPE M-II or CAFCO FENDOLITE TG / ISOLATEK TYPE TG product as it is being applied.

For certain applications, galvanized diamond lath may be used. The lath is secured to the substrate in either a contour or boxed configuration in accordance with Isolatek’s application Instructions and design guidelines.

For storage vessels and spheres, the mesh retention system is installed such that no mechanical fixings are required to be attached to the substrate. The method of installation depends on the type and size of the vessel to be protected.

The CAFCO FENDOLITE M-II or TG / ISOLATEK TYPE M-II or TG is then applied to the surface of the mechanical reinforced substrate in accordance with our written application instructions. Refer to our Application Techniques section for more details regarding the step by step processes used.

CAFCO® FENDOLITE® M-II & TG / ISOLATEK® Type M-II & TG

Maintenance and Repair Procedures of the CAFCO FENDOLITE M-II  / ISOLATEK Type M-II and CAFCO FENDOLITE TG / ISOLATEK Type TG System for Petrochemical Facilities – Short Form.

Routine maintenance performed through testing and inspection of Spray-Applied Fire Resistive Materials (SFRMs) ensures that the product will be in-place for its intended life cycle.

Petrochemical structures are continually exposed to severe environments. As a result, the fireproofing system is susceptible to damage caused by items such as impact and weathering.

A Maintenance program is essential to maintain the integrity of a completely installed fireproofing system. The complete system consists of the steel substrate (i.e. galvanized or primed/coated), metal lath or mesh, anchoring system (i.e. shots, pins, studs and/or wire ties), the fireproofing material, along with the sealer/top coat (if required) and caulking system.

A complete survey of the fireproofing is needed in order to maintain the system and project future cost of the Maintenance Program.

The survey must be conducted by a N.A.C.E. Inspector with knowledge of the fireproofing system, and recommended and approved by Isolatek International.

The procedures outlined below are intended as a guide for conducting your maintenance program. The N.A.C.E. inspector will need a complete copy of the drawings (steel, equipment and support) for mark up, along with access to the project site. The drawings are to remain with owner and/or owner’s rep upon completion of survey.

The N.A.C.E. Inspector will divide the survey in segments (i.e. pipe rack, equipment, HCU unit, Alkyd unit, Diesel unit, etc.) so that all areas and units have their own cost / breakdown for tracking purposes.

1.0 INSPECTION

1.1 The N.A.C.E. Inspector will inspect and record on the drawings all areas of concern including but not limited to locations where:

  1. Fireproofing system is damaged
  2. Corner bead is damaged (if used)
  3. Previous repaired areas
  4. Delamination areas
  5. Cracking
  6. Mildew
  7. Chemical stain/damage areas
  8. Wet areas
  9. Top coat/sealer failure
  10. No caulk or improperly applied caulk
  11. Areas that may have steam discharge onto the system

1.2 The N.A.C.E. Inspector shall submit to the owner and/or owners representative all of the drawings with the mark ups, along with a written procedure to complete all of the necessary repairs of the fireproofing system in accordance with Isolatek International’s guidelines.

2.0 Decision

2.1 Inspector must ascertain which observed items require attention within the current maintenance cycle, based on one or both of the following criteria:

  1. A repair (i.e. fissure or crack) which may allow moisture and chemical ingress / accumulation behind the fireproofing material.
  2. Aesthetic appeal.

3.0 REPAIR

3.1 Termination Seal Delamination and/or Cracking.

  1. Strip away the old caulk to reveal the original surfaces. This must occur a minimum of 6 inches (150 mm) beyond the problem area in both directions.
  2. Re-apply an approved compatible caulk in its place.

3.2 Topcoat Failure

  1. Remove all peeling topcoat by adhering to SSPC-SP 2 (hand tool cleaning).
  2. Ensure surface is free from dust and other contaminants.
  3. Apply new approved topcoat.

3.3 Prior Repair or Patch Failure

  1. Remove existing/damaged patching material down to steel substrate/reinforcement, chamfering sharp edges to leave only sound material
    in place.
  2. Attach a new piece of 3.4 lb/yd² (1.84 kg/m2) expanded metal lath or mesh reinforcement into the void by either attaching to existing reinforcement via No. 18 SWG tie wire, or by attaching to the substrate via powder actuated fastener or studwelder. If hexagonal mesh is used in the original application, attach a new piece of plastic coated hexagonal mesh or mesh of 50mm x 50mm x 1.4mm – 1.6mm
    galvanized hexagonal mesh to the existing mesh using 18 SWG wire ties (or twist cut ends together) and maintain a 2 inch (50 mm) overlap at all joints.
  3. Position the new reinforcement within the middle third of fireproofing thickness.
  4. Pre-wet the existing CAFCO FENDOLITE M-II / ISOLATEK Type M-II fireproofing material.
  5. Apply freshly mixed CAFCO® FENDOLITE® M-II / ISOLATEK Type M-II or CAFCO® FENDOLITE® TG / ISOLATEK Type TG(Trowel Grade) material into the void, taking care to push the material behind the reinforcement and completely filling the void.
  6. Wait approximately 7 to 10 days before re-applying the approved topcoat (if necessary).

3.4 DAMAGE TO CORNER BEAD AND/OR OTHER REINFORCEMENT

  1. Cut away bent or broken corner bead, lath or mesh and strip away adjacent fireproofing a minimum of 6 inches (150 mm) beyond the repair area in all directions down to steel substrate / reinforcement and chamfer all sharp edges leaving only sound material in place.
  2. Attach a new piece of corner bead to the existing 3.4 lb/yd² (1.84 kg/m2 ) expanded metal lath using No. 18 SWG steel tie wire. If hexagonal mesh was used in the original application, attach a new piece as previously described in 3.3.2 above and ensure that it will lie in the mid third of the freshly applied repair thickness.
  3. Pre-wet the existing CAFCO FENDOLITE M-II / ISOLATEK Type M-II fireproofing material surrounding the repair area.
  4. Apply freshly mixed CAFCO FENDOLITE M-II / ISOLATEK Type M-II or CAFCO FENDOLITE TG / ISOLATEK Type TG, flush with surrounding/existing material.
  5. Wait approximately 7 to 10 days before re-applying approved topcoat (if necessary).

3.5 SIGNS OF RUSTING BEHIND FIREPROOFING (BLEED-THROUGH)

  1. Remove all CAFCO FENDOLITE M-II / ISOLATEK Type M-II material to a minimum of a 12 inch (300 mm) radius around the problem area, down to the steel substrate/reinforcement.
  2. Observe rusting of surface of steel. In the case that the project inspector feels that the rusting goes beyond the exposed area, strip away the CAFCO FENDOLITE M-II / ISOLATEK Type M-II until the rusting has ceased.
  3. Strip away existing reinforcement.
  4. Remove loose rust from the steel surface as per SSPC-SP 2/3 Hand and/or Power tool cleaning.
  5. Ensure that the area is free from loose mill scale, oils, dust, or other contaminants.
  6. Apply Epoxy Mastic/DTR or other approved surface tolerant epoxy to the surface. The coating must be compatible with the existing coating and the fireproofing material.
  7. Apply new reinforcement. Attached with powder actuated fastener or studwelder. Studwelds will require additional surface preparation (i.e. grinding down areas to bare metal, pinning, and final touch-up with Mastic/DTR or approved surface tolerant epoxy).
  8. Pre-wet the existing CAFCO FENDOLITE M-II / ISOLATEK Type M-II fireproofing material surrounding the repair area.
  9. Apply freshly mixed CAFCO FENDOLITE M-II / ISOLATEK Type M-II or CAFCO FENDOLITE TG / ISOLATEK Type TG, flush with surrounding/existing material.

The above-mentioned application procedure is applicable to structural steelwork in petrochemical and hydrocarbon processing facilities and shall be read in conjunction with the specific requirements of the client as detailed in any specification prepared for the project.

Unless directed to the contrary in the procedure, CAFCO FENDOLITE M-II / ISOLATEK Type M-II must be stored, mixed, applied, controlled and repaired in accordance with Isolatek International’s latest CAFCO FENDOLITE M-II / ISOLATEK Type M-II, CAFCO FENDOLITE TG / ISOLATEK Type TG, CAFCO FENDOLITE M-II/P / ISOLATEK Type M-II/P Application and Installation Manual.

Should you have further questions pertaining to this matter, please contact the Isolatek International Technical Service Department at 800-631-9600, extension 269.

CAFCO® FENDOLITE® M-II/P / ISOLATEK® Type M-II/P

Maintenance and Repair Procedures of the CAFCO FENDOLITE M-II/P / ISOLATEK Typ M-II/P System for Petrochemical Facilities – Short Form

Routine maintenance performed Routine maintenance performed through testing and inspection of Spray-Applied Fire Resistive Materials (SFRMs) ensures that the product will be in-place for its intended life cycle.

Petrochemical structures are continually exposed to severe environments. As a result, the fireproofing system is susceptible to damage caused by items such as impact and weathering.

A Maintenance program is essential to maintain the integrity of a completely installed fireproofing system. The complete system consists of the steel substrate (i.e. galvanized or primed/coated), metal lath or mesh, anchoring system (i.e. shots, pins, studs and/or wire ties), the fireproofing material, along with the sealer/top coat (if required) and caulking system.

A complete survey of the fireproofing is needed in order to maintain the system and project future cost of the Maintenance Program.

The survey must be conducted by a N.A.C.E. Inspector with knowledge of the fireproofing system, and recommended and approved by Isolatek International.

The procedures outlined below are intended as a guide for conducting your maintenance program. The N.A.C.E. inspector will need a complete copy of the drawings (steel, equipment and support) for mark up, along with access to the project site. The drawings are to remain with owner and/or owner’s rep upon completion of survey.

The N.A.C.E. Inspector will divide the survey in segments (i.e. pipe rack, equipment, HCU unit, Alkyd unit, Diesel unit, etc.) so that all areas and units have their own cost / breakdown for tracking purposes.

1.0 INSPECTION

1.1 The N.A.C.E. Inspector will inspect and record on the drawings all areas of concern including but not limited to locations where:

  1. Fireproofing system is damaged
  2. Corner bead is damaged (if used)
  3. Previous repaired areas
  4. Delamination areas
  5. Cracking
  6. Mildew
  7. Chemical stain/damage areas
  8. Wet areas
  9. Top coat/sealer failure
  10. No caulk or improperly applied caulk
  11. Areas that may have steam discharge onto the system

1.2 The N.A.C.E. Inspector shall submit to the owner and/or owners representative all of the drawings with the mark ups, along with a written procedure to complete all of the necessary repairs of the fireproofing system in accordance with Isolatek International’s guidelines.

2.0 DECISION

2.1 Inspector must ascertain which observed items require attention within the current maintenance cycle, based on one or both of the following criteria:

  1. A repair (i.e. fissure or crack) which may allow moisture and chemical ingress / accumulation behind the fireproofing material.
  2. Aesthetic appeal.

3.0 REPAIR

3.1 Termination Seal Delamination and/or Cracking.

  1. Strip away the old caulk to reveal the original surfaces. This must occur a minimum of 6 inches (150 mm) beyond the problem area in both directions.
  2. Re-apply an approved compatible caulk in its place.

3.2 Topcoat Failure

  1. Remove all peeling topcoat by adhering to SSPC-SP 2 (hand tool cleaning).
  2. Ensure surface is free from dust and other contaminants.
  3. Apply new approved topcoat.

3.3 Prior Repair or Patch Failure

  1. Remove existing/damaged patching material down to steel substrate/reinforcement, chamfering sharp edges to leave only sound material
    in place.
  2. Attach a new piece of 3.4 lb/yd² (1.84 kg/m2) expanded metal lath or mesh reinforcement into the void by either attaching to existing reinforcement via No. 18 SWG tie wire, or by attaching to the substrate via powder actuated fastener or studwelder. If hexagonal mesh is used in the original application, attach a new piece of plastic coated hexagonal mesh or mesh of 50mm x 50mm x 1.4mm – 1.6mm galvanized hexagonal mesh to the existing mesh using 18 SWG wire ties (or twist cut ends together) and maintain a 2 inch (50 mm) overlap at all joints.
  3. Position the new reinforcement within the middle third of fireproofing thickness.
  4. Pre-wet the existing CAFCO FENDOLITE M-II/P / ISOLATEK Type M-II/P fireproofing material.
  5. Apply freshly mixed CAFCO FENDOLITE M-II/P / ISOLATEK Type M-II/P material into the void, taking care to push the material behind the reinforcement and completely filling the void.
  6. Wait approximately 7 to 10 days before re-applying the approved topcoat (if necessary).

3.4 DAMAGE TO CORNER BEAD (IF USED) AND/OR OTHER REINFORCEMENT

  1. Cut away bent or broken corner bead, lath or mesh and strip away adjacent fireproofing a minimum of 6 inches (150 mm) beyond the repair area in all directions down to steel substrate / reinforcement and chamfer all sharp edges leaving only sound material in place.
  2. Attach a new piece of corner bead to the existing 3.4 lb/yd² (1.84 kg/m2) expanded metal lath using No. 18 SWG steel tie wire. If hexagonal mesh was used in the original application, attach a new piece as previously described in 3.3.2 above and ensure that it will lie in the mid third of the freshly applied repair thickness.
  3. Pre-wet the existing CAFCO FENDOLITE M-II/P / ISOLATEK Type M-II/P fireproofing material surrounding the repair area.
  4. Apply freshly mixed CAFCO FENDOLITE M-II/P / ISOLATEK Type M-II/P, flush with surrounding/existing material.
  5. Wait approximately 7 to 10 days before re-applying approved topcoat (if necessary).

3.5 SIGNS OF RUSTING BEHIND FIREPROOFING (BLEED-THROUGH)

  1. Remove all CAFCO FENDOLITE M-II/P / ISOLATEK Type M-II/P material to a minimum of a 12 inch (300 mm) radius around the problem area, down to the steel substrate/reinforcement.
  2. Observe rusting of surface of steel. In the case that the project inspector feels that the rusting goes beyond the exposed area, strip away the CAFCO FENDOLITE M-II/P / ISOLATEK Type M-II/Puntil the rusting has ceased.
  3. Strip away existing reinforcement.
  4. Remove loose rust from the steel surface as per SSPC-SP 2/3 Hand and/or Power tool cleaning.
  5. Ensure that the area is free from loose mill scale, oils, dust, or other contaminants.
  6. Apply Epoxy Mastic/DTR or other approved surface tolerant epoxy to the surface. The coating must be compatible with the existing coating and the fireproofing material.
  7. Apply new reinforcement. Attached with powder actuated fastener or studwelder. Studwelds will require additional surface preparation (i.e. grinding down areas to bare metal, pinning, and final touch-up with Mastic/DTR or approved surface tolerant epoxy).
  8. Pre-wet the existing CAFCO FENDOLITE M-II/P / ISOLATEK Type M-II/P fireproofing material surrounding the repair area.
  9. Apply freshly mixed CAFCO FENDOLITE M-II/P / ISOLATEK Type M-II/P, flush with surrounding/existing material.

The above-mentioned application procedure is applicable to structural steelwork in petrochemical and hydrocarbon processing facilities and shall be read in conjunction with the specific requirements of the client as detailed in any specification prepared for the project.

Unless directed to the contrary in the procedure, CAFCO FENDOLITE M-II/P / ISOLATEK Type M-II/P must be stored, mixed, applied, controlled and repaired in accordance with Isolatek International’s latest CAFCO FENDOLITE M-II / ISOLATEK Type M-II, CAFCO FENDOLITE TG / ISOLATEK Type TG, CAFCO FENDOLITE M-II/P / ISOLATEK Type M-II/P Application and Installation Manual.

Should you have further questions pertaining to this matter, please contact the Isolatek International Technical Service Department at 800-631-9600, extension 269.

 
 

Quality Control Test Data Report (Form # C01A)

In order to provide a method for our customers to monitor and maintain product quality during installation, we have developed the Quality Control Test Data Report (Form # C01A). This method provides a summary of quality as the product is installed and allows means to address non-conformities. At the end of the project there is a record that the product and the installation have met all performance standards and fulfills the Quality Control in Application (Section 9.4) of the API 2218; Fireproofing Practices in Petroleum and Petrochemical Processing Plants. This minimizes future risk and gives applicators, engineers and architects the highest degree of confidence in their fire resistive system.

Our location

ISOLATEK INTERNATIONAL provides passive fireproofing materials under the CAFCO® and FENDOLITE® trademarks throughout the Americas and under the ISOLATEK® trademark throughout the world.

m

Stainless Steel Pins Supplier

ISOLATEK INTERNATIONAL

41 Furnace Street
Stanhope NJ 07874, USA
Tel: 1-800-631-9600

isolatek.com

Plastic Coated Galvanized Hexagonal Mesh Supplier

ISOLATEK INTERNATIONAL

41 Furnace Street
Stanhope NJ 07874, USA
Tel: 1-800-631-9600

isolatek.com

Metal Lath Suppliers

ISOLATEK INTERNATIONAL

41 Furnace Street
Stanhope NJ 07874, USA
Tel: 1-800-631-9600

isolatek.com

3.4 lb/yd² (1.8 kg/m²) galvanized expanded metal lath.

Corner Bead Supplier

ISOLATEK INTERNATIONAL

41 Furnace Street
Stanhope NJ 07874, USA
Tel: 1-800-631-9600

isolatek.com

Plastic nosed, 2” open leg, wire corner bead

Spray-Equipment Manufacturers

Mayco/Essicks

18910 Wilmington Avenue
Carson, CA 90746, USA
Tel: 800-421-1244

FM9 #4 Rotor-Stator Pump (discontinued)
Mixer, EM90SH8, EM90PH8 (plastic drum)
8 cu. ft. (225 liters) paddle & ribbon mixers

Spray-King Mfg. Inc.
3535 North Duke Avenue
Fresno, CA 93727, USA
Tel: 800-448-5555 or 559-291-5586
spraykingmfg.com
#4, #6 rotor/stator pumps
Hydrolic Dump Over, P88 or D88, 200 HYD, 300 HYD,
TH14, Terminator Super 450

Thomsen/ Putzmeister-United States
18620 So. Broadway
Gardena, CA 90248, USA
Tel: 213-321-8380
putzmeister.com
putzmeisteramerica.com
S5-EV (electric), S5-GH (gas)

Strong Mfg.
P.O. Box 8068
Pine Bluff, AR 71611, USA
Tel: 800-238-5042 or 870-535-4753
strongmfg.com
#4, #6 rotor/stator pumps – Spraymate 60

Putzmeister-United Kingdom
Putzmeister Ltd.
Chesterfield Trading Estate
Carrwood Road
S41 9QB
Chesterfield Derbyshire
United Kingdom
+44 (0) 1246-264200
Putzmeister.co.uk
SP-11

Hyflex Corp.
8774 South State Road. 109
Knightstown, IN 46148 USA
Tel: 1 765-571-5125 or 1 866-849-6246
hyflexcorp.com
#4, #6 rotor/stator pumps
HZ-30E (electric), HZ-30G (gas), HZ-30DM (diesel)

Spray-Equipment Distributors
The Donnelly Company
753 Rowley Road
Victor, New York 14564, USA
Tel: 800-624-3530 or 716-924-0640
Putzmeister, Mayco/Essicks, Hyflex, J&M Service Inc., Quickspray Inc., Stone Construction Equipment Inc., Construction Forms Inc.

Nathan Kimmel Company, LLC
1213 South Santa Fe Avenue
Los Angeles, CA 90021, USA
Tel: 800-431-0005 or 213-627-8556
nathankimmel.com
8 cu. ft. (225 liter) paddle & ribbon mixers
American Spray Technology, Hyflex, Multiquip, Putzmeister, QuickSpray Inc., Toro

Walker Equipment
3009 South Jackson Avenue
S. Chicago Heights, IL 60411, USA
Tel: 708-754-7070 or 800-227-7072
walker-equipment.com
Equipment rentals – Putzmeister (S5-EV or S5-GH)

Hardline Services Inc.
PO Box 2884
Fullerton CA 92837
717F S State College Blvd Fullerton CA. 92831Tel: 657-217-0703
Tel: 657-217-5250
Cell: 714-357-8260

Putzmeister, Mayco, Graco, GFI pumps, BR Pumps, Neptune

Spray-Equipment Manufacturers

Mayco/Essicks

18910 Wilmington Avenue
Carson, CA 90746, USA
Tel: 800-421-1244

FM9 #4 Rotor-Stator Pump (discontinued)
Mixer, EM90SH8, EM90PH8 (plastic drum)
8 cu. ft. (225 liters) paddle & ribbon mixers

Spray-King Mfg. Inc.
3535 North Duke Avenue
Fresno, CA 93727, USA
Tel: 800-448-5555 or 559-291-5586
spraykingmfg.com
#4, #6 rotor/stator pumps
Hydrolic Dump Over, P88 or D88, 200 HYD, 300 HYD,
TH14, Terminator Super 450

Thomsen/ Putzmeister-United States
18620 So. Broadway
Gardena, CA 90248, USA
Tel: 213-321-8380
putzmeister.com
putzmeisteramerica.com
S5-EV (electric), S5-GH (gas)

Strong Mfg.
P.O. Box 8068
Pine Bluff, AR 71611, USA
Tel: 800-238-5042 or 870-535-4753
strongmfg.com
#4, #6 rotor/stator pumps – Spraymate 60

Putzmeister-United Kingdom
Putzmeister Ltd.
Chesterfield Trading Estate
Carrwood Road
S41 9QB
Chesterfield Derbyshire
United Kingdom
+44 (0) 1246-264200
Putzmeister.co.uk
SP-11

Hyflex Corp.
8774 South State Road. 109
Knightstown, IN 46148 USA
Tel: 1 765-571-5125 or 1 866-849-6246
hyflexcorp.com
#4, #6 rotor/stator pumps
HZ-30E (electric), HZ-30G (gas), HZ-30DM (diesel)

Spray-Equipment Distributors
The Donnelly Company
753 Rowley Road
Victor, New York 14564, USA
Tel: 800-624-3530 or 716-924-0640
Putzmeister, Mayco/Essicks, Hyflex, J&M Service Inc., Quickspray Inc., Stone Construction Equipment Inc., Construction Forms Inc.

Nathan Kimmel Company, LLC
1213 South Santa Fe Avenue
Los Angeles, CA 90021, USA
Tel: 800-431-0005 or 213-627-8556
nathankimmel.com
8 cu. ft. (225 liter) paddle & ribbon mixers
American Spray Technology, Hyflex, Multiquip, Putzmeister, QuickSpray Inc., Toro

Walker Equipment
3009 South Jackson Avenue
S. Chicago Heights, IL 60411, USA
Tel: 708-754-7070 or 800-227-7072
walker-equipment.com
Equipment rentals – Putzmeister (S5-EV or S5-GH)

Hardline Services Inc.
PO Box 2884
Fullerton CA 92837
717F S State College Blvd Fullerton CA. 92831Tel: 657-217-0703
Tel: 657-217-5250
Cell: 714-357-8260

Putzmeister, Mayco, Graco, GFI pumps, BR Pumps, Neptune

Nozzles/Guns Suppliers

The Donnelly Company
1753 Rowley Road
Victor, New York 14564, USA
Tel: 800-624-3530 or 716-924-0640

Walker Equipment
13009 South Jackson Avenue
S. Chicago Heights, IL 60411, USA
Tel: 708-754-7070 or 800-227-7072
walker-equipment.com

Nathan Kimmel Company, LLC
1213 South Santa Fe Avenue
Los Angeles, CA 90021, USA
Tel: 800-431-0005 or 213-627-8556
nathankimmel.com

Hoses/ Couplings/ Reducers Suppliers

The Donnelly Company
753 Rowley Road
Victor, NY 14564, USA
Tel: 800-624-3530 or 716-924-0640
Parts/accessories – Goodyear Hoses and fittings.
Miscellaneous equipment

Walker Equipment
3009 South Jackson Avenue
S. Chicago Heights, IL 60411, USA
Tel: 708-754-7070 or 800-227-7072
walker-equipment.com
Parts/accessories – Goodyear Hoses and fittings.
Miscellaneous equipment

Nathan Kimmel Company, LLC
1213 South Santa Fe Avenue
Los Angeles, CA 90021, USA
Tel: 800-431-0005 or 213-627-8556
Trusted Advisor Newsletter

FIREPROOFING INSIGHTS

Subscribe for expert insights on code compliance, product selection, and optimizing your fireproofing designs—straight to your inbox.

    Water Booster Pump Suppliers

    Contractors Consulting Services, Inc
    1024 4th Avenue South
    Nashville, TN 37210
    Tel: 615-255-6958
    Boss – Water Booster Pump

    Stainless Steel Mesh Suppliers

    ISOLATEK INTERNATIONAL

    41 Furnace Street
    Stanhope NJ 07874, USA
    Tel: 1-800-631-9600
    isolatek.com
    3.4 lb/yd² (1.8 kg/m²) galvanized expanded metal lath.

    Stainless Steel Anchors Suppliers

    ISOLATEK INTERNATIONAL

    41 Furnace Street
    Stanhope NJ 07874, USA
    Tel: 1-800-631-9600
    isolatek.com

    Sprayer Equipment Manufacturers

    Red Engineering LLC
    22 Dog Branch Road North
    Pleasant Shade, TN 37145
    Tel:  (615) 669-1698

    http://redeng.us/machinery

    Contractors Consulting Services, Inc
    1024 4th Avenue South
    Nashville, TN 37210
    Tel: 615-255-6958
    ccsboss.com
    “Boss” Machines with 2, 5, 7, and 10 Power Packs.
    Small job Fireproofing machines – “Patch Pump”.

    Unisul, Inc
    101 Hatfield Dr.
    Winter Haven, FL 33880
    Tel: 863-294-3206
    Fax: 863-294-6771
    unisul.com
    Poly-Spray C-500
    All pneumatic fireproofing machines.

    PDQuipment
    753 Gasoline Alley, Bensenville, IL 60106
    or
    18493 S. Ferguson Road, Oregon City, OR 97045
    Tel: 888-383-7274
    PDQuipment.com

    Nozzles/Guns Suppliers

    Hydra-Cone, Inc
    3445 Board Road
    York, PA 17402
    Tel: 717-764-5802
    2-1/2 in. (65mm) RA-9 Airless
    2 in. (50mm) RA-6 Airless
    2-1/2 in. (65mm) I.D. Air/Water Low Output
    2-1/2 in. (65mm) I.D. Air/Water High Output

    Contractors Consulting Services, Inc
    1024 4th Avenue South
    Nashville, TN 37210
    Tel: 615-255-6958
    Boss – 6 Jet Airless
    Boss – 8 Jet Airless

    PDQuipment
    753 Gasoline Alley, Bensenville, IL 60106
    or
    18493 S. Ferguson Road, Oregon City, OR 97045
    Tel: 888-383-7274
    PDQuipment.com

    Hoses/ Couplings/ Reducers Suppliers

    Hydra-Cone, Inc
    3445 Board Road
    York, PA 17402
    Tel: 717-764-5802
    Supply Hoses 
    Reducers
    Modular Pole Guns
    Sleeves
    Depth Gauges

    Kuriyana of America
    360 E. State Pkwy
    Schaumberg, IL 60017
    Tel: 847-755-0360
    Fax: 800-800-0320
    Kuriyama.com
    Urevac II (whip hose)
    “WT” Series (transfer)

    PDQuipment
    753 Gasoline Alley, Bensenville, IL 60106
    or
    18493 S. Ferguson Road, Oregon City, OR 97045
    Tel: 888-383-7274
    PDQuipment.com

    CAFCLIP & Clinch Shield Suppliers

    ISOLATEK INTERNATIONAL

    41 Furnace Street
    Stanhope NJ 07874Tel: 1-973-347-1200
    isolatek.com

    Test Kit Suppliers

    Nathan Kimmel Company, LLC
    4876 Alhambra Ave.
    Los Angeles, CA 90032, USA
    Tel: 800-421-0005 or 213-627-8556
    nathankimmel.com
    High Production Yield Kit*
    Density Kit*
    Bond Kit*
    Field Inspection Kit*
    * request CAFCO specific kits

    Hydra Cone, Inc.
    360 E. State Pkwy
    3445 Board Rd.
    York, PA 17406, USA
    Tel: 1-800-673-2437 or 1-717-764-5802
    hydracone.com
    Heavy Pin Model Depth Gauge (650-621)

    Sprayer Equipment Manufacturers

    Thomsen / Putzmeister – United States
    1733 90th Street
    Sturtevant, WI 53177
    Tel: 262-886-3200 or 1-800-884-7210
    Putzmeister.com
    Putzmeisteramerica.com
    S5-EV (electric), S5-GH (gas)
    Big Blue
    Tommy Gun A-3.75

    Hyflex Corp.
    8774 South State Road 109
    Knightstown, IN 46148
    Tel: 1-765-571-5125 or 1-866-849-6246
    Hyflexcorp.com
    321 E Series Piston Pump
    HZ 30 #6 Rotor Stator
    HZ 30G #6 Rotor Stator

    Western Equipment
    1160 Olympic Drive
    Corona, CA 92881
    Tel: 1-951-284-2000
    Western-emi.com
    Predator Piston Pump

    Graco, Inc
    88-11th Ave NE
    Minneapolis, MN 55413
    Tel: 612-623-6000
    Fax: 612-623-6777
    Graco.com
    ToughTek F800E
    ToughTek F340E


    Spray-Equipment
    DistributorsNathan Kimmel Company, LLC
    4876 Alhambra Avenue
    Los Angeles, CA 90032
    Tel: 1-800-421-0005 or 1-213-627-8556
    Nathankimmel.com

    The Donnelly Company
    753 Rowley Road
    Victor, NY 14564
    Tel: 1-800-624-3530 or 1-716-924-0640

    Hardline Services, Inc
    917 South State College Blvd.
    Fullerton, CA 92831
    Tel: 1-657-217-5250 or 1-657-217-0703
    hardlineservices.com

    PDQuipment
    753 Gasoline Alley, Bensenville, IL 60106
    or
    18493 S. Ferguson Road, Oregon City, OR 97045
    Tel: 888-383-7274
    PDQuipment.com

    Nozzles/Guns Suppliers

    The Donnelly Company
    1753 Rowley Road
    Victor, New York 14564, USA
    Tel: 800-624-3530 or 716-924-0640

    Walker Equipment
    13009 South Jackson Avenue
    S. Chicago Heights, IL 60411, USA
    Tel: 708-754-7070 or 800-227-7072
    walker-equipment.com

    Nathan Kimmel Company, LLC
    4876 Alhambra Avenue
    Los Angeles, CA 90032
    Tel: 1-800-421-0005 or 1-213-627-8556
    Nathankimmel.com

    PDQuipment
    753 Gasoline Alley, Bensenville, IL 60106
    or
    18493 S. Ferguson Road, Oregon City, OR 97045
    Tel: 888-383-7274
    PDQuipment.com

    Hoses/ Couplings/ Reducers Suppliers

    Nathan Kimmel Company, LLC
    4876 Alhambra Avenue
    Los Angeles, CA 90032
    Tel: 1-800-421-0005 or 1-213-627-8556
    Nathankimmel.com

    The Donnelly Company
    753 Rowley Road
    Victor, NY 14564
    Tel: 1-800-624-3530 or 1-716-924-0640

    Hardline Services, Inc
    917 South State College Blvd.
    Fullerton, CA 92831
    Tel: 1-657-217-5250 or 1-657-217-0703
    hardlineservices.com

    PDQuipment
    753 Gasoline Alley, Bensenville, IL 60106
    or
    18493 S. Ferguson Road, Oregon City, OR 97045
    Tel: 888-383-7274
    PDQuipment.com

    Hyflex Corp.
    8774 South State Road 109
    Knightstown, IN 46148
    Tel: 1-765-571-5125 or 1-866-849-6246
    Hyflexcorp.com

    Accelerator Injector Pump Suppliers

    Nathan Kimmel Company, LLC
    4876 Alhambra Avenue
    Los Angeles, CA 90032
    Tel: 1-800-421-0005 or 1-213-627-8556
    Nathankimmel.com

    The Donnelly Company
    753 Rowley Road
    Victor, NY 14564
    Tel: 1-800-624-3530 or 1-716-924-0640

    Hardline Services, Inc
    917 South State College Blvd.
    Fullerton, CA 92831
    Tel: 1-657-217-5250 or 1-657-217-0703
    hardlineservices.com

    PDQuipment
    753 Gasoline Alley, Bensenville, IL 60106
    or
    18493 S. Ferguson Road, Oregon City, OR 97045
    Tel: 888-383-7274
    PDQuipment.com

    Hyflex Corp.
    8774 South State Road 109
    Knightstown, IN 46148
    Tel: 1-765-571-5125 or 1-866-849-6246
    Hyflexcorp.com

    Sprayer Equipment Manufacturers

    Graco, Inc
    88 – 11th Ave NE
    Minneapolis, MN 55413
    Tel: 612-623-6000
    Fax: 612-623-6777
    graco.com
    Electric: Graco 1595, Mark V, Mark X (220V)
    Pneumatic: President 46:1, King 45:1
    Gas: GH 5030 Roof Rig

    Titan Tool, Inc
    1770 Fernbrook Lane
    Plymouth, MN 55447
    Tel: 800-526-5362
    Fax: 800-526-4826
    titantool.com
    Electric/Gas: 1200 XLT DI, 6900 XLT DI
    Gas: Hydra M 4000, Hydramax 350
    Pneumatic: Admiral 40:1, Commander 45:1, Admiral 60:1

    Wet Film Gauges Suppliers

    ISOLATEK INTERNATIONAL

    41 Furnace Street
    Stanhope NJ 07874
    Tel: 1-800-631-9600
    isolatek.com
    Intumescent Wet Film Gauge

    Dry Film Gauges Suppliers

    Elcometer, Inc
    1093 Rochester Industrial Drive
    Rochester Hills, MI 48309
    Tel: 800-521-0635
    Fax: 248-650-0501
    elcometer.com
    Model 456 (range 0 – 500 mils, 0 – 13mm)

    Defelsko Corp
    802 Proctor Ave
    Ogdensburg, NY 13669
    Tel: 800-448-3835
    Fax: 315-393-8471
    defelsko.com
    Model Positector 6000 FT2 (range 0 – 250 mils, 0 – 6mm)

    Shore D Gauges Suppliers

    PTC Instruments
    753 Pacific Transducer Corp
    230 Federal Ave
    Los Angeles, CA 90064
    Tel: 310-478-1134
    Fax: 310-312-0826
    ptc1.com

    Hose/Gun Suppliers

    Graco, Inc
    88 – 11th Ave NE
    Minneapolis, MN 55413
    Tel: 612-623-6000
    Fax: 612-623-6777
    graco.com
    Electric: Graco 1595, Mark V, Mark X (220V)
    Pneumatic: President 46:1, King 45:1
    Gas: GH 5030 Roof Rig

    Titan Tool, Inc
    1770 Fernbrook Lane
    Plymouth, MN 55447
    Tel: 800-526-5362
    Fax: 800-526-4826
    titantool.com
    Electric/Gas: 1200 XLT DI, 6900 XLT DI
    Gas: Hydra M 4000, Hydramax 350
    Pneumatic: Admiral 40:1, Commander 45:1, Admiral 60:1

    Spray-Tech
    1770 Fernbrook Lane
    Plymouth, MN 55447
    Tel: 1-800-292-4637
    spraytechnic.com
    Electric: EP 2510
    Gas: GPX 130/165/220

    Screws, Pins & Non-Return Washers Suppliers

    Nelson Stud Welding
    7900 West Ridge Road
    Elyria, OH 44036, USA
    Tel: 1-800-634-9353
    nelsonstudwelding.com
    10 ga. TPC single pointed insulation pin
    10 ga. CHP cupped head insulation pin

    SFS Intec
    1045 Spring Street
    Wyomissing, PA 19610
    Tel: 610-376-5751
    sfsintecusa.com
    Dekfast #12 Philips or Hex Head Screws
    3″ Round Stacked Galvalume Plate, M7685

    Creative Display Works, Inc
    3621 E. Wier Ave
    Phoenix, AZ 85040
    Tel: 602-295-3014
    Contact: Tim “Milo” Miloserny
    Tel:: 602-295-3013
    creativedisplayworks.com
    3” washers 
    Made in the USA

    Weld Equipment:

    Nelson Stud Welding
    7900 West Ridge Road
    Elyria, OH 44036, USA
    Tel: 1-800-634-9353
    nelsonstudwelding.com
    CD Lite I, Nelweld N800i

    Cutlass Fasteners, Inc.
    83 Vermont Ave., Unit 6,
    Warwick, RI 02888 USA
    Tel: 1-401-732-6333
    cutlass-studwelding.com
    Classic or Pinto Stud Welding System

    Foil Tape Suppliers

    Silver Faced Board:

    Venture Tape
    30 Commerce Road
    Rockland, MA 02370, USA
    Tel: 1-781-331-5900
    venturetape.com
    1520CW – 2 Mil Aluminum Foil Tape

    Thermafiber, Inc.
    3711 Mill Street
    Wabash, IN 46992, USA
    Tel:. 1-888-834-2371
    thermafiber.com
    Aluminum Foil Tape 3

    White Faced Board:

    Venture Tape
    30 Commerce Road
    Rockland, MA 02370, USA
    Tel: 1-781-331-5900
    venturetape.com
    1558HT High Tack White Aluminum Foil Tape

    Weld Equipment Suppliers

    Nelson Stud Welding
    7900 West Ridge Road
    Elyria, OH 44036, USA
    Tel: 1-800-634-9353
    nelsonstudwelding.com
    CD Lite I, Nelweld N800i

    Cutlass Fasteners, Inc
    83 Vermont Ave., Unit 6,
    Warwick, RI 02888 USA
    Tel: 1-401-732-6333
    cutlass-studwelding.com
    Classic or Pinto Stud Welding System

    Sprayer Equipment

    Sprayer Equipment Manufacturers

    Contractor’s Consulting Services

    1024 4th Ave South
    Nashville, TN 37210

    Model Number

    Pack 5
    Pack 7
    Pack 10
    *Disc Set at 12

    Unisul (CertainTeed)

    20 Moores Road
    Malvern, PA 19355

    Model Number

    Poly-Spray* Carding Box Fully open

    Cool Machine

    740 Fox Road
    Van Wert, OH 45891
    Tel: 419-232-4871

    Model Number

    2400
    1500

    Krendl Machine Company

    1201 Spencerville Ave
    Delphos, OH 45833
    Tel: 419-692-3060

    Model Number

    475
    575
    2300

    Accu1Direct, Inc.

    138 Denslow Rd
    East Longmeadow, MA 01028
    Tel: 800-438-2776

    Model Number

    9700
    9800